SECURITY ALARM SYSTEM | ||
Oxygen Concentration Alarm | Upper Limit Setting Range | 21%~99% |
Low Limit Setting Range | 18%~80% | |
Airway Pressure Alarm | Upper Limit Setting Range | 5~60 cmH2O |
Low Limit Setting Range | 0~50 cmH2O | |
Minute Ventilation Volume Alarm | Upper Limit Setting Range | 1~20L/min |
Low Limit Setting Range | 0~19L/min | |
Tidal Volume | Upper Limit Setting Range | 10~1800ml |
Low Limit Setting Range | 0~1700ml | |
Respiratory Rate | Upper Limit Setting Range | 10~99bPm |
Low Limit Setting Range | 0~50 bPm | |
Sustained High-pressure
Alarm |
It will give alarm when stress have consistently been higher than 30 cmH2O. | |
Suffocation Alarm; Gas Shortage Alarm; Low Pressure of Oxygen Alarm; Low Pressure of Air Alarm; Power Alarm; Intubation off Alarm; Battery Voltage Alarm | ||
Power | AC220V, 50Hz.
UPS, Storage Battery |
|
Manipulator |
AR-202 Ventilator
SECURITY ALARM SYSTEM | ||
Oxygen Concentration Alarm | Upper Limit Setting Range | 21%~99% |
Low Limit Setting Range | 18%~80% | |
Airway Pressure Alarm | Upper Limit Setting Range | 5~60 cmH2O |
Low Limit Setting Range | 0~50 cmH2O | |
Minute Ventilation Volume Alarm | Upper Limit Setting Range | 1~20L/min |
Low Limit Setting Range | 0~19L/min | |
Tidal Volume | Upper Limit Setting Range | 10~1800ml |
Low Limit Setting Range | 0~1700ml | |
Respiratory Rate | Upper Limit Setting Range | 10~99bPm |
Low Limit Setting Range | 0~50 bPm | |
Sustained High-pressure
Alarm |
It will give alarm when stress have consistently been higher than 30 cmH2O. | |
Suffocation Alarm; Gas Shortage Alarm; Low Pressure of Oxygen Alarm; Low Pressure of Air Alarm; Power Alarm; Intubation off Alarm; Battery Voltage Alarm | ||
Power | AC220V, 50Hz.
UPS, Storage Battery |
|
Manipulator |
Related products
AED-5000 Automated External Defibrillator
Specifications and Features
Specifications
Type: Automatic External Defibrillator AED
Self-test: Daily, Weekly, Monthly
Mode: Adult, Child
Waveform: Biphasic truncated exponential
Energy: 200 Joule max.
Energy Sequence (programmable): 50,50,75 Joule
150, 150, 200 Joule
Charge time (at 25℃): Less than 6 sec. to 150J
Less than 8 sec. to 200J
AED-7000 Automated External Defibrillator
Technical Specifications
--Portable Automated External Defibrillator (AED)
--It is easy to operate and use. It requires low for operator and can be equipped for household or public; and supply first-aid to the abrupt death promptly
--Adopting ECG analysis advanced technology of ARI Company, it can analyze the patient’s ECG to judge the heart’s state, whether to defibrillate and its energy. It can not only improve the success rate, also reduce the hurt to heart to lowest degree
--Pulse Type: Biphasic Waveform
--Three-step defibrillation process
--Two-button operation
--Extensive voice and visual prompts for the operator
--Continuous event recording for reporting each use to a printer or computer
--Weekly self-test to ensure readiness
--Biphasic energy output
--Lock-out protection to prevent inadvertent defibrillation
ESU-K500 Ultrasonic Scalpel
Clinical Advantages
- The cutting and coagulation can be finished at the same time;
- Can close the blood vessels under 3mm safely;
- No current through the patient’s body;
- Minimum tissue eschar and desiccation;
- Precise cutting under the minimum thermal damage;
- Little smog;
- Multifunctional, and reduce the equipment replacement.
Overbed Table
8” color TFT screen, optional touchscreen
-User friendly design interface
-Tidal volume 5~1500 ml
-Up to 6 flow tubes for 3 gases
-PPSU/Metallic material of breathing circuit
-By-pass Tech for soda lime canister
-All ventilation modes to satisfy neonate, pediatric and adult patients
-Integrated breathing circuit with built-in heater
-Highly visible ACGO
ESU-2000AI (LED) Electrosurgical Unit
Features
- Max 400W Electrosurgical Generator, with mono-polar and bipolar function.
- Nine working modes: pure cut,blend1, blend2, blend3, contact coag, forced coag, soft coag, bipolar coag, bipolar cut
- The electrosurgical generator is used to control bleeding and surgical cutting in all general and open surgical procedures, such as the general surgery, thoracic surgery,
brain surgery, ENT surgery, etc.
- With different audible and visual indication during the process of outputting.
- Patient return electrode monitoring system and Power Peak System that provides
surgeons with improved performance at Lower power settings, minimizing the risk of
tissue damage.
- Applicable for Prostate Vaporizing Surgical Operation (TUR), perfectly used under water. The electrosurgical generator can be cooperated with endoscope and laparoscope.
- Pencil Remoting Output. The output power can be controlled by the add or subtract button on the remoting control pencil.
T.IB Electrical Surgical Pendant
Features
- The control cabinet of tower crane adopts imported high-strength aluminum alloy for the one-off extrusion molding, and the surface undergoes the primary oxidation treatment.
- Aluminum molding tray with non-slip texture
- Mechanical friction damping brake
- lmported motor, cantilever with lift up and down electrically and rotation function,precise positioning without drift
- Gas pipeline, power supply and computer communication line are arranged without interference.
- The tower adopts German standard gas terminal (over 20,000 of inserting and pulling out)
AML700D LED Surgical Lamp
- Simple and clear operating system.
- Buckle type plugin detachable sterilized handle, easy to clean and sterilize.
- PWM Dimming System, Color Temperature Flexibly Adjustable.
- One button to change lighting mode: Standard, endoscope, low light lighting.
- Adjustable field diameter.
- German Osram LED, high light efficiency, with Average Lifespan over 50,000hrs.
- Optical PMMA Lens, aluminum board heat dissipation, unique collecting technology, low energy consumption and high light efficiency
M-9000E Patient Monitor
Technical Specification
ECG
Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)
Lead selection: I, II, III, avR, avL, avF, V,
Waveform: 2 ch
Gain: ‘2.5mm/mV, ‘5.0mm/mV, ‘10mm/mV, ‘20mm/mV, auto
Heart Rate and Alarm
Range
Adult: 15 ~ 300 bpm
Neo/Ped: 15 ~ 350 bpm
Accuracy: ± 1% or ± 1bpm, which great
Resolution: 1 bpm
ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV