AED Mode
AED Function: Auto analyzes and charges x3 with programmable auto energy level selection, screen prompts, and voice prompts.
Shockable Rhythms: Ventricular fibrillation with amplitude≥200UV, Ventricular tachycardia with rates≥140bpm, and QRS complex wave duration≥140ms.
Charge Control: Control on device front panel, press key on paddle.
Prompts: Voice and visual prompts.
Manual Mode
Energy Selection: Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 Joules.
Synchronized Mode: Synchronizes defibrillator pulse to patient’s R-wave. “SYNC” message displayed on monitor.
ECG Monitoring
Patient Connection: 5-lead ECG cable, or 3-lead ECG cable, paddles.
Lead Selection: Displayed on monitor, paddles, l, II, III, AVR, AVL, AVF, V.
ECG Size: 0.25, 0.5, 1, 1.5, 2, 4 cm/mV display on monitor.
Heart Rate: 20-300BPM.
Heart Rate Alarm: On/Off displayed on monitor, user-selectable.
Smart Alarms: Beeper/Voice prompts indicate shockable rhythm.
SpO2 Module
Measurement Range: 30-100%, +2% between 80%-90%, others + 5%
Alarm Range: User set high limit and low limit
Alarm Accuracy: +10% within setting values
Alarm Time Accuracy: Less than 12 sec
Recorder
Paper: 50mm thermal.
Speed: 12.5mm/sec, 25mm/sec, 50mm/sec. User-selectable 6-second delay.
Printing Method: High-resolution, thermal array print head.
Print-out Modes: Manual or automatic, user-configurable.
On/Off Control: Front panel and paddle.
Automatic Function: 9-second recording initiated by alarm activation or defibrillator charge or defibrillator discharge.
Battery
Type: Rechargeable, Ni-MH battery, 12V.
Operating Time: For a new, fully charged battery: 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring.
Additional parameters will affect operating time with different functions.
Option 1
Specification | Pacer (Optional) |
Type | VVI |
Pulse Type | Rectangular, constant current |
Pulse Amplitude | 0 to 180 mA±10% or 5 mA (whichever is greater) |
Pacing Rate | Variable from 30ppm to 180ppm±1.5% (increments or decrements by a value of 2ppm) |
Multi-Function Electrode (MFE) Pads | Multipurpose defibrillator/pacing electrodes |
Pause | Pacing pulse frequency reduced by a factor of 4 when activated |
Refractory Period | NC (VVI demand do not have this specification) |
Pulse Width | (20+1.5ms) |
Output Protection | Fully defibrillator protected and isolated |
Option 2
Specification | EtCO2 (Optional) |
Type of sensor | By-pass |
Technical principle | Non-dispersive infrared gas analysis NDIR |
Storage condition | -40℃ to 70℃, <90℃ RH, non-condensing |
Operating conditions | 5℃ to 50℃, 10 to 90℃ RH, non-condensing |
Ambient pressure | 55-115kPa |
Power supply | 5V±5% (max ripple 200mVp-p) |
TDP | Typical value 120mA Excursion calibration typical value 280mA |
Range | 0-19.7% (0-150mmHg, or 0-20Kpa) |
Resolution | 0.1mmHg |
Accuracy | 0-40mmHg±2mmHg
41-70mmHg±5% of reading 71-100mmHg±8% of reading 101-150mmHg±10% of reading |
Respiratory rate | 2-150BPM |
Respiratory rate measurement accuracy | 1%±1BPM |
Option 3
Specification | NIBP (Optional) |
Measurement unit | mmHg/kPa |
Measurement Range | Adult: 10~200mmHg/kPa
Pediatric: 10~200mmHg/kPa Neonatal: 10~135mmHg/kPa |
Resolution | 1mmHg |
Accuracy | Maximum mean error: 5mmHg
Maximum standard deviation: 8mmHg |
Type of sensor | By-pass |
Technical principle | Non-dispersive infrared gas analysis NDIR |
Storage condition | -40℃ to 70℃, <90% RH, non-condensing |
Operating conditions | 5℃ to 50℃, 10 to 90% RH, non-condensing |
Ambient pressure | 55-115kPa |
Power supply | 5V±5% (max ripple 200mVp-p) |
TDP | Typical value 120mA Excursion calibration typical value 280mA |
Range | 0-19.7% (0-150mmHg, or 0-20kPa) |
Resolution | 0.1mmHg |
Accuracy | 0-40mmHg±2mmHg
41-70mmHg±5% of reading 71-100mmHg±8% of reading 101-150mmHg±10% of reading |
Respiratory rate | 2-150BPM |
Respiratory rate measurement accuracy | 1%±1BPM |